TagNoise Remedy Program(52)
-
2026-07-15
Sea-Tac Communities Plan: Plan Summary Brochure
The Sea-Tac Communities Plan, jointly developed by the Port of Seattle and King County beginning in 1973, outlines strategies to improve compatibility between Sea-Tac International Airport and surrounding neighborhoods, with a focus on aircraft noise remedies, water quality improvements, and land use conversion. The plan identifies specific areas for outright property acquisition, purchase guarantees, and noise insulation programs affecting thousands of homes north and south of the airport. It also establishes policies for drainage management, community development, and long-term airport facility improvements to accommodate projected air traffic growth through 1993. -
2026-07-15
Sea-Tac Communities Plan: Plan Summary Brochure
Plan Summary brochure for the Sea-Tac Communities Plan (STCP), a joint Port Of Seattle and King County Council initiative begun March 1973 to achieve compatibility between Sea-Tac Airport and surrounding communities. Covers water quality programs for Miller Creek and Des Moines Creek basins including holding pond systems sized via Storm Water Management Model (SWMM); airport -
2026-07-15
Sea-Tac Communities Plan background and environmental findings
This document summarizes the Sea-Tac Communities Plan, a 1973 joint study by the Port of Seattle and King County to improve compatibility between Sea-Tac International Airport and its surrounding neighborhoods. The plan examined aircraft noise exposure, air and water quality, and community growth, finding that noise levels were expected to decrease over time due to quieter aircraft technology despite rising flight operations. It proposed a range of noise remedy programs—including property acquisition, purchase guarantees, and insulation assistance—affecting thousands of homes in areas north and south of the airport. -
2026-07-15
Sea-Tac Communities Plan background and environmental findings
This document summarizes the Sea-Tac Communities Plan, a 1973 joint study by the Port of Seattle and King County to improve compatibility between Sea-Tac International Airport and its surrounding neighborhoods. The plan examined aircraft noise exposure, air and water quality, and community growth, finding that noise levels were expected to decrease over time due to quieter aircraft technology despite rising flight operations. It proposed a range of noise remedy programs—including property acquisition, purchase guarantees, and insulation assistance—affecting thousands of homes in areas north and south of the airport. -
2026-05-04
Acoustical Testing Results for SEA Repair and Replacement Program
Technical memorandum from Harris Miller Miller & Hanson (HMMH) to Julie Kinzie, Sr. Environmental Program Manager Sound Insulation, reporting acoustical testing results for the Seattle-Tacoma International Airport (SEA) Repair and Replacement Program, March 2026. HMMH measured median interior Day-Night Average Sound Level (DNL) for 30 residential structures in Des Moines, Burien, and Seattle using HBK -
2026-05-04
Acoustical Testing Results for SIRRPP — May 2026
Harris Miller Miller & Hanson Inc. (HMMH) conducted sound insulation testing at 30 homes near Seattle-Tacoma International Airport (SEA) in March 2026 to measure how much aircraft noise penetrates indoors. The study found that none of the 30 homes exceeded the FAA's 45-decibel interior noise threshold required to qualify for sound insulation treatments under current federal policy. However, nine homes had at least one individual room where interior noise levels surpassed 45 decibels, suggesting those specific rooms could benefit from upgraded windows or doors. -
2025-12-18
Port Of Seattle Response Letter to Des Moines Mayor Traci Buxton: Sound Insulation Repair and Replacement Pilot Program
The Port of Seattle wrote to Des Moines Mayor Traci Buxton in December 2025 to explain its Sound Insulation Repair and Replacement Pilot Program, a $5 million initiative aimed at helping homeowners near Seattle-Tacoma International Airport whose aging sound insulation packages may no longer be performing adequately. The program focuses on homes that received insulation before 1993 and are located within the FAA-approved Noise Remedy Boundary, with eligibility determined by acoustic testing showing interior noise levels at or above 45 dB DNL. Of the 117 homes tested in the initial phase, five were found eligible, and the Port plans to expand outreach to an additional 209 homes in early 2026 while pursuing FAA grant funding that could cover up to 80% of design and construction costs. -
2025-12-18
Port Of Seattle Response Letter to Des Moines Mayor Traci Buxton: Sound Insulation Repair and Replacement Pilot Program
Letter dated December 18, 2025 from Port Of Seattle Commission President Toshiko Hasegawa to Des Moines Mayor Traci Buxton responding to City Council concerns about the Sound Insulation Repair and Replacement Pilot Program (SIRRPP). Details eligibility requirements: homes inside FAA-approved Noise Remedy Boundary, sound-insulated prior to January 1, 1993, testing at or above 45 dB -
2025-10-10
Acoustical Testing Results for SIRRPP — October 2025
In September 2025, acoustical engineers tested 29 homes near Seattle-Tacoma International Airport to measure how much aircraft noise penetrates indoors. The study found that none of the homes exceeded the 45-decibel interior noise threshold required to qualify for federally funded soundproofing treatments, though 10 homes had at least one room above that level. The findings are part of SEA's Repair and Replacement Program, which evaluates whether previously soundproofed homes need updated windows and doors. -
2025-10-10
Acoustical Testing Results for SEA Repair and Replacement Program
Technical memorandum from Harris Miller Miller & Hanson Inc. (HMMH), authored by Eric Cox, to Julie Kinzie at Seattle-Tacoma International Airport (SEA), reporting acoustical testing results for the SEA Repair and Replacement Program conducted September 2025. HMMH measured median interior Day-Night Average Sound Level (DNL) values for 29 residential structures in SeaTac and Burien using